Objectives of Parts I, II and III
A recent literature has emerged using animal models to simulate the physiological impact from exposure of human children to “thirdhand e-cigarette aerosol”, to be denoted by the aconym “THEA”. The series of posts Part I, Part II and Part III provides a critique of these animal models.
Summary of previous research. Third Hand Smoking (THS): complex phenomenology measurable in the laboratory and in all smoking environments (including those with children occupancy). THEA: single effect (adsorbed nicotine in indoor surfaces) only measurable under special and abnormal conditions. So far, measurable THEA effects have not been found in normal environments where children live and day to day vaping takes place. All this follows from the vast differences between environmental aerosols from smoking and vaping.
“Translational Relevance”. Animal models simulating children exposure to THEA have no Translational Relevance: they simulate a phenomenon that occurs in the environment of an animal model, but according to available evidence it has not been detected in the human environment these studies attempt to simulate. So far, there is no evidence (experimental and observational) of measurable THEA in environments with children occupancy (homes where adult occupants vape, nurseries, schools).
This post Part II
Peculiarities of the exposure in animal models.
Literature search: A PRISMA search revealed 8 mouse studies simulating children exposure to THEA: four from Australia, four from the US.
Detailed review of the 8 studies.
Risk model of nicotine dermal exposure.
Next post Part III
Kinetic model of nicotine adsorption
Why THEA is detected in animal models but not in normal human environments? This is explained by the scale dependence of nicotine adsorption and the very special environment of animal models
Color code in this post: RED = “third hand” & BLUE = “second hand”
Some methodological issues of animal models on vaping:
Rodents are the most common animal species used in the laboratory. I will consider in this post only mice. These are the main characteristics and limitations of mouse studies.
On simulations
The overall purpose of animal models on exposure to vaping aerosols (or any other phenomenon) is to simulate an observed exposure of humans in the controlled environment of an animal model.
It is obvious that proposed simulations in animal models do not reproduce a real life environment (simulations never do).
Animal models must consider in their experimental set up the differences between mice and humans in physiological reactions to exposure (inhalation, ingestion, dermal) and in metabolism
On aerosol generation
Most authors of animal models on exposure to vaping regard a rigorous conduction of biological protocols as the only really relevant scientific issue. They tend to regard aerosol generation as a secondary technical issue, failing to provide sufficient information on aerosol parameters (devices, power, coils, puffing parameters).
This attitude is questionable and unprofessional: aerosol generation is an essential part in experiments probing its effects on in vivo and in vitro systems. A rigorous conduction of appropriate biological protocols to assess effects of exposure to the aerosol does not excuse lack of information on the aerosol causing these effects.
Even having conducted an impeccable biological protocol, reported effects from exposure to toxic or unrepresentative aerosols are irrelevant to assess vaping safety and to guide public health policy. Unfortunately, quite a few authors are unaware and/or careless on the quality of the aerosol used to expose laboratory animals
Vaping aerosol is not a generic “black box” to be used with arbitrary parameters for exposing mice. Aerosol generation and environmental conditions must be adjusted appropriately to avoid exposing mice to toxin loaded aerosols unrepresentative of real life vaping.
.
Peculiarities of the exposure.
Since rodents do not inhale through the mouth, there are two main approaches to examine exposure to vaping aerosol:
Direct nose exposure. Mice are placed in a tight compartment that prevents their motion and a (typically diluted) aerosol current is supplied directly to their noses.
Whole body exposure. Mice inside an exposure chamber are full body exposed to an aerosol current (typically diluted), generating an atmosphere of mixed aerosol with air. Since mice are obsessive groomers (lick their fur), dermal and ingestion exposure can be as important (or more) than inhalation.
Notice: Only the ‘direct nose’ mode involves exposure to a primary aerosol, while the ‘whole body’ mode is really an over-dense concentrated “second hand” exposure to EVA.
Diverse exposure routes
Whole body exposure involves nose inhalation in an atmosphere of air mixed with vaping aerosol. However, mice are also subjected to dermal exposure and to ingestion, since they are compulsive groomers constantly licking their fur.
However, the pattern of their exposure through dermal and ingestion routes might not be an appropriate proxy for human exposure through these routes in indoor spaces where day to day vaping takes place (homes and public spaces where vaping is allowed without excessive simultaneous puffing).
Aerosol dilution: an important points to notice:
Animal models do not (typically) expose mice directly to an aerosol generated by a vaping machine, but to a diluted aerosol flowed though conducts or tubes from the vaping machine to the exposure chamber. It is important to understand the effects of this dilution.
Dilution at ambient temperature and pressure involves increasing the volume of a solution or mixture, thus decreasing the concentration (and possibly aerosol temperature) but without modifying the mass of its constituents.
Most mouse studies expose mice to an aerosol that has been diluted, typically by using tubing conducts to flow each puff of the machine generated aerosol to the inhalation chambers. Some studies mix the aerosol with air besides flowing it.
Authors (and peer reviewers) often assume that a diluted aerosol is safer or less toxic because its concentration decreases. This is not correct. Flowing an aerosol through tubing involves the following phase changes:
it modifies the partition between particles (droplets) and gas, some droplets evaporate into the gas phase and some gas molecules nucleate and form new droplets, but these are phase changes that do not modify the total mass of each compound in the aerosol.
it modifies the mass fraction of droplets in the aerosol, will modify numbers and diameters, some droplets collide and form larger droplets (coagulation), some collide and settle into the tube walls, some evaporate.
it modifies the mass fraction of gas in the aerosol, more gas as some droplets evaporate and less gas if some molecules nucleate to form new droplets (condensation) in the tube.
However, the mass of the toxins contained in the total aerosol will not be modified. The phase changes from the tubing will (at most) pass toxins found in the droplets to the gas phase and vice versa.
For example, tubing the aerosol will not decrease the exposure of mice to formaldehyde and other aldehydes normally found in the gas phase, as they are very volatile and most likely will not nucleate into new droplets because of their small molecular mass.
One study (Zaman et al among the 8 selected studies) claims that diluting and mixing the aerosol somehow “recreates” a “second hand” EVA. As I show in the review of the studies this assumption is mistaken.
Few studies analyze the chemical content of the atmosphere inside the exposure chambers. However, those that have analyzed it corroborate that dilution does not “clean” the aerosol from toxins (see Section 4.5 of https://doi.org/10.2478/cttr-2025-0019)
Animal models on THEA
Literature search
Data base: PubMed (NLM); Scopus| Search date: 27 October 2026
Applied filters: None (to include “grey” and too recent sources).
Search strategy (String): (”third hand e-cigarette aerosol” OR “THEA” OR “third hand vaping” OR “thirdhand vape” OR “third-hand vape”) AND (”mice” OR “mouse” OR “murine” OR “animal model*” OR “children exposure”)
Flow chart
The 8 studies found in the literature search are
Australian studies
Chen, H., Li, G., Allam, V. S. R. R., Wang, B., Chan, Y. L., Scarfo, C., ... & Oliver, B. G. (2020). Evidence from a mouse model on the dangers of thirdhand electronic cigarette exposure during early life. ERJ Open Research, 6(2). https://doi.org/10.1183/23120541.00022-2020
Thorpe, A. E., Donovan, C., Kim, R. Y., Vindin, H. J., Zakarya, R., Miyai, H., ... & Oliver, B. G. (2023). Third-hand exposure to e-cigarette vapour induces pulmonary effects in mice. Toxics, 11(9), 749. https://doi.org/10.3390/toxics11090749
Donovan, C., Thorpe, A. E., Yarak, R., Coward-Smith, M., Pillar, A. L., Gomez, H. M., ... & Kim, R. Y. (2024). Maternal thirdhand exposure to e-cigarette vapor alters lung and bone marrow immune cell responses in offspring in the absence or presence of influenza infection. American Journal of Physiology-Lung Cellular and Molecular Physiology. https://doi:10.1152/ajplung.00078.2024
Oliver, B. G., Wang, J., Yarak, R. A., Hikasem, T., Wang, B., Feng, M., ... & Chen, H. (2025). Exposure to third hand e-cigarette vapour impairs cognitive function in young mice. Ecotoxicology and Environmental Safety, 291, 11788. https://doi.org/10.1016/j.ecoenv.2025.117885
US studies
Commodore, S., Sharma, S., Ekpruke, C. D., Pepin, R., Hansen, A. M., Rousselle, D., ... & Silveyra, P. (2023). Thirdhand vaping exposures are associated with pulmonary and systemic inflammation in a mouse model. Journal of environmental exposure assessment, 2(4), 22. https://dx.doi.org/10.20517/jeea.2023.27
Umphres, S. S., Alarabi, A. B., Ali, H. E., Khasawneh, F. T., & Alshbool, F. Z. (2024). Investigation of the impact of thirdhand e-cigarette exposure on platelet function: A pre-clinical study. Tobacco Induced Diseases, 22, 10-18332. https://doi.org/10.18332/tid/185286
Umphres, S. S., Alarabi, A. B., Ali, H. E., Qadri, S., Khasawneh, F. T., & Alshbool, F. Z. (2026). The Prothrombotic Phenotype of Thirdhand Electronic Cigarette Exposure is Sex Independent and Involves Systemic Mediated Effects on Platelet Function: Evidence from a Mouse Model. Cardiovascular Toxicology, 26(3), 30. https://doi.org/10.1007/s12012-026-10093-z
Zaman, A., Cook, T., Mabou, D. B., Schexnayder, M., Xiao, R., Perveen, Z., ... & Noël, A. (2026). Sex-specific modulation of lung function and transcriptome in neonate mice exposed to thirdhand electronic-cigarette aerosols. Pediatric Research, 1-16. https://doi.org/10.1038/s41390-026-05282-z
Experimental exposure protocols & parameters
As mentioned in Part I, all 8 studies follow roughly the same protocol applied in the order of this numbered sequence
Action: textile fabric samples (towels, carpets, upholstery) inside small inhalation chambers are exposed to substantial aerosol mass
Purpose: to simulate exposure of same fabrics to Environmental Vaping Aerosol (EVA) in human inhabited indoor spacesAction: the aerosol soaked samples are subsequently transferred to cages inhabited by young or neonate mice.
Purpose: to simulate a human habitat with fabrics exposed to EVAAction: some of the mice are placed in cages together with aerosol soaked samples for long periods (typically 2 hours/day 5 days/week for 6 weeks).
Purpose: to simulate children exposed to THEAAction: some of the mice are placed in cages with clean unexposed samples Purpose: to serve as controls.
The specifics of mice exposure.
The 8 selected studies simulating exposure to THEA (as the vast majority of animal models on vaping) considered whole body exposure. However, they examine a specific exposure distinct from the exposure in other animal models on vaping. Instead of exposing the mice directly to the aerosol atmosphere, they examine the exposure of mice to textile samples that were previously exposed to vaping aerosol. Hence, mice are exposed by dermal & ingestion routes to nicotine and other compounds deposited and adsorbed in the samples, but also to inhalation of compounds that might have been “out-gassed” and re-emitted.
Summary of biological and physiological effects.
The main conceptual purpose behind the animal models on THEA is to examine biological and physiological consequences of the exposure of mice to nicotine and the toxins accumulated in aerosol contaminated samples in their cages. Mice will be exposed via dermal, ingestion and inhalation routes. The main biological effects examined are
Local pulmonary inflammation. Changes in lung cells, asthma or damage to pulmonary tissue (Chen, Thorpe, Donovan, Commodore, Zaman)
Systematic cardiovascular effects (Umphres 2024, 2026)
Cognitive deterioration (Oliver)
A more detailed summary is displayed in the table below
I apologize if this information is not accurate, as these topics are outside my expertise
Summary of experimental data
The following table displays for each of the 8 studies found in the literature search the aerosol generation parameters: vaping devices, power/coil, e-liquids, puffing protocol, exposed samples and volume of exposure chamber). This table serves as reference for the review of the studies.
Review of the studies
Australian studies
Aerosol generation, exposure and samples. Three of the 4 Australian studies (Chen 2020, Thorpe 2023, Oliver 2025) followed almost exactly the same aerosol generation protocol and handling of samples established by the first study (Chen et al 2020), with one study (Donovan et al 2024) using a different device.
Vaping device. Aerosol was generated by NEBOX; (KangerTech, Shenzhen, China) at power 30 W and 0.5 Ω coil resistance.
E-liquids. Two, one tobacco flavored in a 50/50 PG/VG mixture,
Nicotine levels. one e-liquid without nicotine the other with 18 mg/mL
Puffing protocol. 20 puffs. Only two studies specify puff duration (5 seconds).
Exposed samples. cotton towels 15 X 10 cm
Exposure chamber. sealed 9 L (0.009 m3) volume
Sample handling procedure. After 20 puffs aerosol exposure the samples were left standing for 2 h in the exposure chamber. Each day afterwards, a freshly exposed towel was placed in the mouse cage (Balb/C, 4 weeks old).
Note. One of the Australian studies (Donovan 2024) used the same e-liquids, nicotine levels handling of samples, but puffed a different device and coils: Vaporesso GenS, (Shenzhen, China) in these power/coil combinations 30 W with 4Ω and 60 W with 1.4 Ω.
Criticism
An obsolete device. The NEBOX used by 3 of the 4 studies is a third generation sub-ohm device released in 2015. It is now technologically outdated and is no longer available in retailers in North America and in the EU.
The only retailer found by an AI aided google search was a webpage dated 7 years ago (May 2019) reporting the device as being “out of stock”. The same google search provides links of demonstration videos by users, all dated before 2016.
Yet, this museum piece device was used by three of the 4 studies (Chen at al, Thorpe et al and Oliver et al) that the latter two published in 2023 and 2025. Perhaps, the authors had no access to more updated devices given the Australian prohibition of sale of commercial vapes (even for research purpose).
Nonsensical information. Donovan et al 2024 used a more updated sub-ohm device (Vaporesso GenS), but their power and coil resistance combinations (30 W with 4 Ω and 60 W with 1.4 Ω) are completely nonsensical. Coils of 4Ω are used in industrial processes, never in vapes and much less at 30 W, while applying 60 W to a coil 1.4 Ω, would immediately melt its thin wires. Most likely, there was a typo on the authors’ description. Nevertheless, information on the aerosol is lost.
Contradictory parameters and missing information. The 4 studies mention having generated aerosol by a “human e-cigarette machine” (??), which denotes more a vaping device for human usage than a puff simulation instrument (vaping machine, or syringes). The authors provide no description of how aerosol was generated and collected, on how it was delivered to the exposure chamber. To mention only a sequence of 20 puffs at 30 W and 0.5 Ω is not sufficient to assess the type of aerosol they generated.
There is plenty of confusing and contradictory information. One study (Oliver et al 2025) mentions a puff volume of 50 mL, citing a study on vaping topography that does not justify this number. Oliver et al also mentioned that each puff produced a ~3 µL condensate, but without explaining how this condensate was produced. Another study (Thorpe et al 2023) describes the 20 consecutive puffs applied to the towels as “a total potential exposure or loading of 250 mL of e-cigarette aerosol/towel over a 2 h period”, but there is no explanation to justify these 250 mL. All this information is confusing, contradictory and useless to assess what sort of aerosol was used to expose the towels.
Unrealistic nicotine levels. The 4 studies used used sub-ohm de vices to generate aerosol from e-liquids with 18 mg/mL nicotine concentration, when consumers puffing sub-ohm devices use e-liquids with low nicotine concentrations below 6 mg/mL. Puffing a device at 30 W with 18 mg/mL would produce a strong irritation.
Summary
These 4 studies are a “test case” illustrating how careless and amateurish are many authors of animal models on describing aerosol generation. I criticized the study by Oliver et al 2025 in this PubPeer comment
https://robertosussman.substack.com/publish/post/222580141
However, I focused more on a critique based on the translation between human scales and scales of mouse inside small cages.
Studies from the US
Aerosol generation and exposure
All 4 American studies generated aerosols with commercially sold exposure systems: the InExpose of SCIREQ (Commodore 2023, Zaman 2026) and the e-vapeTM vapor inhalation system from La Jolla Alcohol Research (Umphres 2024, 2026). Only Umphres 2024, 2026 provided sufficient information on aerosol generation, while information provided by Commodore 2020 on temperature mode can only be verified operating the InExpose. However, Zaman et al 2026 provided very insufficient information.
Commodore et al 2023 only mention using the SCIREQ system with coil resistance 1.5 Ω and temperature 230°C. They do not identify the mod (thus we can assume they used the EVIC mini, the default supplied by SCIREQ). The system delivered 3.3 s puffs every 30 s during one hour (120 puffs) with puff volume of 70 mL (airflow of 1.27 L/min) into samples (cotton towels of 120 cm2) placed in a 5 L exposure chamber. The e-liquid was an unflavored 50/50 PG/VG mixture with 6 mg/mL nicotine concentration.
As shown by Soulet et al, the coil resistance 1.5 Ω in SCIREQ allows for an optimal aerosol generation for supplied powers 10-40 W, with around 10-15 mg/puff generated (assuming the device was puffed in this range of powers). Although there is uncertainty in the screen readings in devices operated in temperature control mode, it likely that aerosol generated by Commodore et al was not in the overheating regime.
Umphres et al 2024, 2026 provided full information on aerosol generation and exposure protocol. Aerosol was generated in the two studies using a TFV8 Big Baby tank in the La Jolla exposure system, set with 5 V and resistance 0.4 Ω (power 62 W), with menthol favored e-liquid, PG/VG ratio 30/70 and nicotine concentration 18 mg/ml.
They delivered a barbaric amount of 400 daily puffs for 5 consecutive days (total 2000 puffs) into a closed chamber of 81 in3 (0.005 m3). The samples were: one piece (12 in × 3.5 in) fiber upholstery, three pieces (7.5 in × 5.5 in) cotton fabric, and two pieces (2 in × 2 in) fiber carpets (area 0.002 m2 carpet and 0.027 m2 the other samples).
Zaman et al 2026 provide very insufficient information on aerosol generation, a serious flaw that makes their study very hard to assess. They used the SCIREQ InExpose to deliver 3 s puffs every 30 s (puff volume 55 mL leading to airflow 1 L/min). E-liquid was a 25/75 PG/VG mixture with 24 mg/mL nicotine. However, they do not specify the number of delivered puffs, the device mod attached to the custom made SCIREQ tank, the coil resistance or any other information (power, voltage or temperature).
The terrycloth and carpet samples were exposed to an aerosol that was diluted with a nebulizer, which Zaman et al claim should simulate a “surrogate second hand aerosol” spiced with saline to humidify it. The exposed samples were placed in the mice cages 2 hours per day for 5 days. However, the authors provide no information on the samples area and on the dilution and humidification process.
Criticism
Commodore 2023. They generated an aerosol without sub-ohm resistance (1.5 Ω) and nicotine concentration consistent with consumer usage. It is likely the only study that generated an aerosol that human users would puff.
Umphres et al 2024, 2026. As a contrast with Commodore et al, generated an enormous aerosol mass (2000 puffs) with a powerful su-ohm device (62 W) from an e-liquid with nicotine concentration of 18 mg/mL. As commented regarding the Australian studies, this is an excessive nicotine concentration that strongly deviates with consumer usage of sub-ohm devices.
However, the worse shortcoming of both studies by Umphres et al is the exposure of samples to a gargantuan mass of an aerosol (400 daily puffs in 5 days) that we can confidently assume was generated under overheating conditions: a sub-ohm device (TFV8 Big Baby tank in the La Jolla exposure system), with resistance 0.4 Ω puffed at 62 W with airflow 1 L/min.
The samples (upholstery, cotton, carpet) were exposed in a small sealed chamber of 0.005 m3 to a massive quantity of 2000 puffs. In a PubPeer comment I evaluated 51,200 mg or aerosol and 460 mg of nicotine (see reference at the end). This massively delivered was loaded with aldehydes and other organic toxins and possibly also high yields of metals.
Evidently, the mice were exposed (mostly by dermal and ingestion routes) to samples necessarily overloaded by adsorbed nicotine and other toxins. In the next follow up post (Part III) I will prove with a kinetic model that surface density swipes of nicotine in these samples (specially the carpet) are 5 orders of magnitude above any swipe density of THS measured in experiments and observations.
I criticized the second paper of Humphres et al in this PubPeer comment
https://pubpeer.com/publications/2ED0097D6126B6FC7FE5392773ED9B
The comment explains the evaluation of aerosol and nicotine masses. It has some errors, but provides a simple analytic model of nicotine adsorption
Zaman 2026. Given their lack of information on aerosol generation, we cannot know if they also used 24 mg/mL with a sub-ohm device. They mention that their exposure model “aligns with previous work in our laboratory”, citing in their reference 42 (Cahill 2022), who used the InExpose with resistance 0.15 Ω at 4.2 V, which as shown in our paper on studies using the InExpose leads to an overheating regime. However, we cannot assume that Zaman et al used the same parameters.
Zaman et al claim that they simulated a “surrogate second hand aerosol” by flowing the aerosol through a nebulizer and spicing it with saline to humidify it, in order to mimic the highly humid environment of respiratory tracts. The whole arrangement is shown in a schemtic figure without further explanation. The claim of a surrogate second hand aerosol is mistaken: this process adds compounds (the saline) that are not present inside respiratory tracts and can hardly emulate the phase changes in these tracts, specially it fails to emulate the users’ retention of ~90% of the inhaled aerosol.
Zaman et al measured total particle numbers (TPN), nicotine and formaldehde in the samples and in the air inside the exposure chamber (see summary in the Pub Peer comment cited at the end). Concentrations were significantly higher than in any human habitat. They compared their TPNs with PM2.5 measured in extreme events like vape fests 10 years ago in which hundreds of users simultaneously vaped.
They recognize that their study involves a “high-exposure scenario” consistent with extreme vaping environments, which are hardly compatible with children’s habitats, where children wold be exposed to THEA. They recognize “high-exposure scenario” deep inside within their paper. One wonders why not recognize it in the abstract, but this recognition is clearly incompatible with the narrative of the article.
Although it is possible (but would be highly speculative) to infer the aerosol generation parameters from the information they provide on nicotine and TPM inside the mice cages, their lack of information on aerosol generation and dilution is a serious flaw that strongly detracts its quality.
Pub Peer comments.
I published a Pub Peer comment criticizing Zaman et al
https://pubpeer.com/publications/52C0C57CEDFA74913090297194D80D
In another PubPeer comment
https://pubpeer.com/publications/F8ED5EED3A21D1F97754F063F56535
I criticize an Australian MD who assumes that THEA (third hand e-cigarette aerosol) is a generic feature of vaping that places risks to children whose parents vape at home. He gave a positive evaluation of Zaman et al
Dermal exposure to nicotine
There is legitimate concern on dermal exposure to THS , specially children’s exposure, as there is solid evidence of its measurable presence in normal indoor environments where smoking takes place, even after smoking has been discontinued and even in environments with children occupancy. As I argued in my published review, theoretical, experimental and observational evidences on third hand vaping (THEA) do not justify the same level of concern as with THS.
Practically all observational (out of laboratory) field study evidence on THS and THEA is based on surface density swipes (in µg/m2 or mg/m2) of adsorbed nicotine and its byproducts (including TSNAs) in indoor surfaces, with the difference that measurable swipes of THEA have been found only in indoor environments unrepresentative of normal “day to day” vaping.
Some of the measured density swipes are quite quite high. Typically 200 µg/m2 (nicotine) and 10-20 ng/m2 (TSNAs) in intense smoking environments. Researchers (Khatchatoorian et al 2019) placed for one month a terrycloth towel lying on top of a desk counter inside a vape shop operating in 2016 (thus a situation unrepresentative of normal vaping environments), measuring gargantuan densities of 108 mg/m2 (nicotine) and hundreds of ng/m2 (TSNAs).
Although the concern for dermal exposure is a legitimate public health issue, specially on small children and toddlers, the risk of dermal exposure must be handled carefully, since most scenarios of dermal manipulation by adults and children involve a minute fraction of area of skin contact and very short times.
In other words: the fact that a significantly high nicotine swipe of (say) 1 mg/m2 is measured on a 1 m2 towel or carpet, does not translate into a dermal exposure to 1 mg of nicotine, because most likely only 10-20 cm2 of the fabric are manipulated for less that 30 s. Exposure to 1 mg of nicotine would require touching or licking every single squared centimeter of the fabric.
However, there is a scenario that warrants concern because of the likelihood of long manipulation times: toddlers or young children crawling on horizontal fabrics (bed linen or floor carpets) that engage in manipulating fabrics (towels, rugs, furniture) and in prolonged mouth to hand motion. I addressed this issue in Section 6 of my published review.
Risk model of dermal exposure to adsorbed nicotine
For a quantitative analysis I considered the chronic exposure assessment of the risk model of USEPA RAGS (the US Environmental Protection Agency Risk Assessment Guidance for Superfund, Volume I: Human Health. Evaluation Manual, Part E, Supplemental Guidance for Dermal Risk Assessment) for the dermal route of organic compounds in water, since adsorbed nicotine forms thin liquid layers on indoor surfaces. The risk model must be applied to specific exposure scenarios and be based on chemical and physical parameters of skin absorption.
Risk is quantified by comparing the daily dose ADDabs with a toxicological marker suitable to nicotine dermal exposure. The USEPA RAGS formula for the ADDabs is (see equation 3.1 )

where SA is the skin area (cm2) available for contact, EV is the event frequency (N events per day), BW is body weight (70 kg adults, 10 kg toddlers) and DAevent is the absorbed nicotine dose per event, whose computation requires input from physical and chemical properties of skin absorption and of nicotine. I am not including in this post the explicit detailed computation of DAevent. Readers are invited to read this computation in the Appendix of my published review.
To compare ADDabs with a toxicological benchmark, I assumed the following two scenarios
Scenario 1. Short-duration dermal hand contact with samples by adults. We can assume 200 events/day, with tevent = 10 s and contact surface area SA = 15 cm2,(from the combined area of the thumb, index, and middle fingers comprising roughly 0.1% of the average body surface area of 1.7 m2.
Scenario 2. Longer duration dermal contact by toddlers (1–2 years old). From observational in evidence in Chapter 16 of USEPA Exposure Factors Handbook, toddlers spend on average 771 min/d = 12.85 h/d in their bedroom (Table 16—15 of) and engage in 20 events of hand-to-mouth activity per hour (Table 4.1), each lasting 30 s, leading to 240 events. For the skin area exposed we assume also SA = 15 cm2 (even if toddlers’ hands are small, their dermal manipulation might involve larger proportion of body surface).
An appropriate toxicological benchmark to compare with ADDabs is the Acceptable Daily Intake (ADI) of 0.0008 mg/kg body weight per day for nicotine derived by the European Food Safety Agency (EFSA). Although the ADI of EFSA is an ingestion Reference Dose (RfDoral), it can be used to extrapolate a dermal Reference Dose (RfDabs) through the relation RfDabs = RfDoral X ABSgi, where ABSgi is the fraction of the compound absorbed in the gastrointestinal tract (see equation 4.3 of USEPA RAGS ).
Since 50–90% of consumed nicotine is converted to cotinine and excreted by urine (see Benowitz et al 2009), we can assume ABSgi to be sufficiently close to unity to regard the EFSA’s ADI as a good dermal reference marker for nicotine. To evaluate safety, we compute the ratio ADDabs/ RfDabs, where is the ADI of EFSA 0.0008 mg/kg body weight per day for the two scenarios and different values of nicotine density swipes (sigma) that have been measured in smoking homes.
The following figure displays ADDabs compared with the ADI of EFSA as a function of N (number of events) for nicotine density swipes sigma ranging from light smoking (3 µg/m2) to heavy smoking (50 µg/m2) (see reference).
Notice that the ADI of EFSA (the safety benchmark RfDabs) is only surpassed for many dermal events at the highest level of smoking (50 µg/m2), with safe levels for lower level of smoking. The relative safety follows from the short duration and small area of skin contact.
The following figure depicts Scenario 2, defined to be reflective to toddlers engaged in longer time dermal manipulation and nicotine density swipes measured in a home with children occupancy (see reference)
Notice that longer time skin contact in toddlers significantly increases risks, even if nicotine density swipes are lower than in Scenario 1. The safety marker of the ADI of EFSA is overtaken for three of the four density swipes at a relatively low number of events. Safety after 240 events only occurs for the lowest level 2 µg/m2 in homes where smoking indoors was banned.
Conclusion.
Take away message on dermal risks. This risk analysis shows that nicotine density swipes do not determine themselves dermal exposure risks. This means that 200 µg/m2 in a 1 m2 towel in a home does not mean that occupants face dermal exposure to 200 µg of nicotine, but the safety of their dermal exposure depends on the details of a given exposure scenario. As the analysis show, toddlers face higher risks than adults.
The “air to skin” exposure. This is an exposure route I have not examined. It is not really THS, as it is produced by deposition of air nicotine in the “second and” ETS into human skin, hair and clothes. This exposure has been verified in this article
Bekö, G.; Morrison, G.; Weschler, C.J.; Koch, H.M.; Pälmke, C.; Salthammer, T.; Schripp, T.; Toftum, J.; Clausen, G. Measurements of dermal uptake of nicotine directly from air and clothing. Indoor Air 2017, 27, 427–433 (reference)
This air to skin exposure is measurable from smoking but not from vaping. The reason is the difference in physicochemical properties. ETS releases to the indoor environment a substantial aerosol mass with highly reactive content from the mainstream and side stream emissions.
As a contrast, the “second hand” EVA releases a a significantly lower aerosol mass only from users’ exhalation and with 5-10% of the inhaled nicotine as the single reactive compound (PG and VG are not reactive at ambient temperatures)
Finally, the risk analysis was conducted on THS because there is field evidence of significantly measurable nicotine density swipes in normal smoking environments. To conduct this analysis on vaping (THEA) would be practically impossible, since there is no evidence of significantly measurable nicotine density swipes in normal smoking environments.





